Test conditions
- Filler loading
- 8 %
This record has a different flame-retardant system, baseline, date and standards from the 5%/10%/15% trial. Read it separately. The title names both PA6 and PA66 without separate results.
Swipe to compare all columns ↔
| Property | Standard / condition | Unit | Baseline | 8% |
|---|---|---|---|---|
| Density | GB/T 1033 | g/mL | 1.40 | 1.41 |
| Tensile strength | GB/T 1040 | MPa | 100 | 103 |
| Elongation at break | GB/T 1040 | % | 7 | 7.5 |
| Flexural strength | GB/T 9341 | MPa | 115 | 125 |
| Flexural modulus | GB/T 9341 | MPa | 5600 | 5800 |
| Notched impact strength | GB/T 1843 | kJ/m² | 9.5 | 10.2 |
| Ash / glass-fibre content (source label) | GB/1635 | % | 33.5 | 33 |
| Glow-wire time at 880°C | GB/T 5169 | s | 10 | 10 |
| Glow-wire observation at 760°C | GB/T 5169 | — | No burning reported | No burning reported |
| Vertical burning rating | UL 94 | T1 / T2 | V0 | V0 |
The ash / glass-fibre standard is printed “GB/1635” and is retained without substituting another standard. UL 94 specimen thickness, full glow-wire criteria, standard editions and dosage basis are not provided. V0 is not an independent certification claim.
02Source and conditions
Source: 超细纤维添加各个行业的测试数据.pdf, PDF pp. 1. Test date: 2025-08-25. No named testing organisation or report number is given.
These records compare the listed formulations and are not guaranteed values for every grade. Full raw-material grades, batches, specimen counts and repeatability are not supplied. Repeat the trials with the intended materials and process.