Test conditions

Filler loading
8 %

This record has a different flame-retardant system, baseline, date and standards from the 5%/10%/15% trial. Read it separately. The title names both PA6 and PA66 without separate results.

Swipe to compare all columns ↔

Baseline versus 8% formulation
PropertyStandard / conditionUnitBaseline8%
DensityGB/T 1033g/mL1.401.41
Tensile strengthGB/T 1040MPa100103
Elongation at breakGB/T 1040%77.5
Flexural strengthGB/T 9341MPa115125
Flexural modulusGB/T 9341MPa56005800
Notched impact strengthGB/T 1843kJ/m²9.510.2
Ash / glass-fibre content (source label)GB/1635%33.533
Glow-wire time at 880°CGB/T 5169s1010
Glow-wire observation at 760°CGB/T 5169—No burning reportedNo burning reported
Vertical burning ratingUL 94T1 / T2V0V0

The ash / glass-fibre standard is printed “GB/1635” and is retained without substituting another standard. UL 94 specimen thickness, full glow-wire criteria, standard editions and dosage basis are not provided. V0 is not an independent certification claim.

02Source and conditions

Source: 超细纤维添加各个行业的测试数据.pdf, PDF pp. 1. Test date: 2025-08-25. No named testing organisation or report number is given.

These records compare the listed formulations and are not guaranteed values for every grade. Full raw-material grades, batches, specimen counts and repeatability are not supplied. Repeat the trials with the intended materials and process.