Test conditions

Filler loading
5 / 10 / 15 %

Trial objective: replace part of a halogenated flame retardant with whiskers, comparing baseline, 5%, 10% and 15% formulations. PA6 and PA66 are not reported separately. The percentage basis and flame-retardant grade are unspecified.

Swipe to compare all columns ↔

Full property comparison
PropertyStandard / conditionUnitBaseline5%10%15%
DensityISO 1183g/cm³1.581.501.531.55
Tensile strengthISO 527MPa104117125124
Elongation at breakISO 527%5.05.26.56.2
Flexural strengthISO 178MPa139157173167
Flexural modulusISO 178MPa5800645067006600
Notched impact strengthISO 180kJ/m²8.110.211.310.6
Glow-wire recorded timeIEC 60695s6535
Glow-wire ignition observationIEC 60695—No ignition reportedNo ignition reportedNo ignition reportedNo ignition reported
Vertical burning ratingUL 94—V0V0V0V0
Heat deflection temperatureISO 75°C202202203203

At 10%, tensile strength rises from 104 to 125 MPa, flexural strength from 139 to 173 MPa, and notched impact from 8.1 to 11.3 kJ/m². At 15%, they fall back to 124, 167 and 10.6. Verify cost and performance in the customer formulation; 10% is not a universal optimum.

Standard editions, glow-wire temperature, UL 94 specimen thickness and HDT load are not supplied. V0 is the recorded rating, not a product certification. The source unit “Glass” for vertical burning is presented here as a rating.

02Source and conditions

Source: 超细纤维添加各个行业的测试数据.pdf, PDF pp. 2. Test date: 2025-07-16. No named testing organisation or report number is given.

These records compare the listed formulations and are not guaranteed values for every grade. Full raw-material grades, batches, specimen counts and repeatability are not supplied. Repeat the trials with the intended materials and process.