These three comparisons use different formulations and units and must not be ranked across tables. The first says nylon without a PA grade; the second specifies unactivated whiskers; the third compares equal loadings of whiskers and wollastonite.
Swipe to compare all columns ↔
| Property | Standard / condition | Unit | Blank | 30% |
|---|---|---|---|---|
| Tensile strength | D638 | kg/cm² | 635 | 835 |
| Tensile modulus | D638 | kg/cm² | 2.33×10⁴ | 4.53×10⁴ |
| Flexural strength | D790 | kg/cm² | 879 | 1208 |
| Flexural modulus | D790 | kg/cm² | 2.13×10⁴ | 4.03×10⁴ |
| Notched impact strength | D256 | kgf·cm/cm | 4.72 | 3.4 |
| Heat deflection temperature | D648 | °C | 65 | 90.5 |
Swipe to compare all columns ↔
| Property | Unit | 100% PA6 | PA6 + 15% GF + 15% CSW | PA6 + 30% GF |
|---|---|---|---|---|
| Tensile strength | MPa | 70 | 147 | 129 |
| Elongation at break | % | 45 | 10 | 13 |
| Flexural strength | MPa | 78 | 218 | 167 |
| Flexural modulus | MPa | 2345 | 8540 | 6210 |
| Notched impact strength | kJ/m² | 5.5 | 14 | 13 |
| Unnotched impact strength | kJ/m² | 130 | 55 | 57 |
Swipe to compare all columns ↔
| Property | Standard / condition | Unit | Whisker | Wollastonite |
|---|---|---|---|---|
| Tensile strength | ASTM D638-2010 | MPa | 95.9 | 77.0 |
| Flexural strength | ASTM D790-2010 | MPa | 216 | 178 |
| Flexural modulus | ASTM D790-2010 | MPa | 13528 | 13862 |
| Notched impact strength | ASTM D256-2010 | J/m | 102 | 86 |
Trade-offs remain: 30% whisker reduces notched impact from 4.72 to 3.4; the hybrid lowers elongation from 13% to 10% and unnotched impact from 57 to 55 kJ/m² versus 30% glass fibre; whiskers give a lower flexural modulus than wollastonite, 13528 versus 13862 MPa. Verify stiffness, toughness and processing together. The first table retains the source units without conversion; the second supplies no standards.
02Source and conditions
Source: 超细纤维添加各个行业的测试数据.pdf, PDF pp. 3. Test date not supplied. No named testing organisation or report number is given.
These records compare the listed formulations and are not guaranteed values for every grade. Full raw-material grades, batches, specimen counts and repeatability are not supplied. Repeat the trials with the intended materials and process.