Test conditions
- Process
- masterbatch / direct film blowing
PBAT-1: 30% filler; PBAT-2 and PBAT-3: 45%; PBAT-4: 30%, using a 75%-filled masterbatch mixed at 1:1.5 before film blowing. The filler is a whisker/calcium-carbonate system with an unspecified internal ratio. Other differences between PBAT-2 and PBAT-3 are not explained.
Swipe to compare all columns ↔
| Property | Unit | PBAT-1 | PBAT-2 | PBAT-3 | PBAT-4 | Standard / condition |
|---|---|---|---|---|---|---|
| Thickness | mm | 0.04 | 0.04 | 0.05 | 0.05 | — |
| Transverse tensile strength | MPa | 16.21 | 8.91 | 10.79 | 15.09 | GB/T 1040.3; 23°C; 200 mm/min |
| Transverse strain at break | % | 608 | 452 | 520 | 731 | GB/T 1040.3; 23°C; 200 mm/min |
| Longitudinal tensile strength | MPa | 18.01 | 12.69 | 13.00 | 19.38 | GB/T 1040.3; 23°C; 200 mm/min |
| Longitudinal strain at break | % | 218 | 163 | 205 | 380 | GB/T 1040.3; 23°C; 200 mm/min |
| Transverse tear strength | kN/m | 83.50 | 59.05 | 63.84 | 84.84 | QB/T 1130; 23°C; 200 mm/min |
| Longitudinal tear strength | kN/m | 86.35 | 69.30 | 72.32 | 73.20 | QB/T 1130; 23°C; 200 mm/min |
| Puncture force | N | 1.08 | 0.77 | 0.97 | 1.09 | GB/T 37841; 23°C; 50 mm/min |
Versus PBAT-1, PBAT-2 drops from 16.21 to 8.91 MPa in transverse strength and from 1.08 to 0.77 N in puncture force. PBAT-4 has higher longitudinal strength but lower longitudinal tear strength, 86.35→73.20 kN/m, with thickness increasing from 0.04 to 0.05 mm. Do not select a formulation by a single maximum. The source prose and tabulated film thickness differ in magnitude; only the specimen-table thicknesses are used here.
This is a mechanical and processing reference. No degradation rate, composting conditions or related certification is supplied; it does not establish certified biodegradability of the finished product.
02Source and conditions
Source: 超细纤维添加各个行业的测试数据.pdf, PDF pp. 8. Test date not supplied. No named testing organisation or report number is given.
These records compare the listed formulations and are not guaranteed values for every grade. Full raw-material grades, batches, specimen counts and repeatability are not supplied. Repeat the trials with the intended materials and process.